Выполнен
Заказ
1201481
Раздел
Иностранные языки
Тип работы
Антиплагиат
Не указан
Срок сдачи
15 Апр 2018 в 23:59
Цена
Договорная
Блокировка
10 дней
Размещен
12 Апр 2018 в 14:40
Просмотров
249
Описание работы
WRITING
5. Read the text and write an abstract. The length of the abstract is 100–120 words (see Appendix).
LIMITATIONS
The amount of power that can be sent over a transmission line is limited. The origins of the limits vary depending on the length of the line. For a short line, the heating of conductors due to line losses sets a thermal limit. If too much current is drawn, conductors may sag too close to the ground, or conductors and equipment may be damaged by overheating. For intermediate-length lines on the order of 100 km (62 mi), the limit is set by the voltage drop in the line. For longer AC lines, system stability sets the limit to the power that can be transferred. Approximately, the power flowing over an AC line is proportional to the cosine of the phase angle of the voltage and current at the receiving and transmitting ends. Since this angle varies depending onsystem loading and generation, it is undesirable for the angle to approach 90degrees.
Very approximately, the allowable product of line length and maximum load is proportional to the square of the system voltage. Series capacitors or phase-shifting transformers are used on long lines to improve stability. High-voltage direct current lines are restricted only by thermal and voltage drop limits, since the phase angle is not material to their operation.
Up to now, it has been almost impossible to foresee the temperature distribution along the cable route, so that the maximum applicable current load was usually set as a compromise between understanding of operation conditions and risk minimization. The availability of industrial Distributed
Temperature Sensing (DTS) systems that measure in real time temperatures all along the cable is a first step in monitoring the transmission system capacity. This monitoring solution is based on using passive optical fibers as temperature sensors, either integrated directly inside a high voltage cable ormounted externally on the cable insulation.
A solution for overhead lines is also available. In this case the optical fiber is integrated into the core of a phase wire of overhead transmission lines (OPPC). The integrated Dynamic Cable Rating (DCR) or also called Real
Time Thermal Rating (RTTR) solution enables not only to continuously monitor the temperature of a high voltage cable circuit in real time, but to safely utilize the existing network capacity to its maximum. Furthermore it
provides the ability to the operator to predict the behavior of the transmission
system upon major changes made to its initial operating conditions.
Нужна такая же работа?
  • Разместите заказ
  • Выберите исполнителя
  • Получите результат
Гарантия на работу 1 год
Средний балл 4.96
Стоимость Назначаете сами
Эксперт Выбираете сами
Уникальность работы от 70%
Нужна аналогичная работа?
Оформи быстрый заказ и узнай стоимость
Гарантированные бесплатные доработки
Быстрое выполнение от 2 часов
Проверка работы на плагиат
Темы журнала
Показать ещё
Прямой эфир